MSR voltage data loggers use configurable analogue inputs to record voltage signals or the analogue outputs of external sensors. Depending on the model and ordered configuration, supported unipolar voltage ranges extend up to 0–48.0 V. The number of inputs, maximum recording rate, memory and data-access method differ substantially between models.
Compare MSR voltage data loggers
Analogue inputs and input ranges must be selected in the product configuration. Check the linked product page before ordering.
Installations that benefit from an integrated display and external-sensor power control
Optional 4 configurable 12-bit inputs; selectable configurations include voltage ranges up to 0–48.0 V
1 reading per second to one reading every 12 hours
More than 2 million measured values
USB; 4-row backlit LCD; rechargeable 2,300 mAh battery; configurable switching power supply for external sensors
Three decisions to make before ordering
1. Input range and resolution
Select the smallest supported input range that still covers the complete expected signal. The listed analogue inputs use 12-bit conversion, but resolution alone does not define total measurement accuracy. Include the external sensor, wiring and complete signal chain when assessing uncertainty.
2. Sampling rate
The MSR160 records up to 1,000 readings per second per analogue channel. The MSR145 reaches up to 50 readings per second, subject to configuration. The wireless MSR145WD, MSR145W2D and the MSR255 record analogue inputs at up to 1 reading per second.
3. Channels and data access
Choose enough analogue channels for every signal that must be recorded simultaneously. Then decide whether USB is sufficient or whether the application benefits from WiFi, Bluetooth, cloud transfer or an integrated display.
Documented voltage-measurement application
Otto Bock Mobility Solutions: electric wheelchair product development
During field testing of the ParaGolfer electric wheelchair, Otto Bock engineers used MSR145 and MSR160 data loggers over several weeks. Sensors connected to four analogue inputs recorded current, voltage, speed and temperature. The MSR160 recorded these values at 16 Hz, and the optional microSD memory allowed more than one billion measured values to be stored.
Frequently asked questions about voltage data loggers
Does every listed logger include voltage inputs as standard?
No. The required analogue-input configuration must be selected when configuring or ordering the logger. Eg. the MSR255 analogue inputs are explicitly optional, and the configurable models offer different numbers of inputs and input ranges.
Can these loggers record 0–48 V directly?
A 0–48.0 V input configuration is available for the models compared above. The connected signal must remain within the configured range. Mains voltage must not be connected directly.
Can the same loggers record 0–20 mA or 4–20 mA signals?
Yes, appropriate current-input configurations are also documented. See the current data logger category for the corresponding selection.
Which model has the highest analogue sampling rate?
The MSR160 has the highest documented analogue rate among these models: up to 1,000 readings per second per channel.
Is 12-bit resolution the same as measurement accuracy?
No. Resolution describes the number of digital levels available from the converter. Overall accuracy also depends on the logger input, the selected range, the external sensor, wiring, noise and calibration.
Need help configuring a voltage data logger?